Home Inspection Reporting Language

Translated from English to Spanish

Un Estilo de Escribir los Informes de las Inspecciones de Viviendas

Traducido de Inglés al Español

  

copyright © Arlene Puentes 2006 All Rights Reserved
Please Review These Restrictions on The Use of This Text

 

Home inspectors and other building professionals may use this reporting language in its English and/or Spanish version in written or oral reports to report individual defects or conditions observed during a particular property inspection.

No other use or reproduction of this text library is allowed. This includes but is not limited to electronic or "soft copy" forms such as website text, pre-packaged report writing software and promotional materials used to sell or promote any product or service.

You alone assume full responsibility for the use of the language you choose to use in your reports.

 

See Also
También Vea:

Main Navigation Page

La Página de la Navegación Principal

Exterior

Limitations/Limitaciones

Interiors/Interiores

 

October Home Inspections

 

Dictionary
Diccionario

 

 

aluminum

aluminio

 

aluminum wiring (solid conductor aluminum branch circuit wiring)

cableado de circuitos derivados con conductores sólidos de aluminio

 

amperage

amperaje

capacidad

 

armored cable -- bx

cables armados

 

bonded

enlazado

enlazar (v. to bond)

 

bonding jumper

borne de enlace

borne de tierra

 

branch circuit

circuito ramal 

 

breaker

interruptor automático

 

 

breaker (double pole)

interruptor automático bipolar

 

bus bar

reglata

 

bushing

boquilla

 

cable, ungrounded cable

aka: hot wire, black

cable de carga

cable de fase

hilo de corriente

 

cable, grounded conductors

aka: neutral, white

cable (blanco) neutro

hilo neutro

hilo de retorno

 

cable (armored – bx)

cables armados

 

cable (cloth covered )

cables con cubierta textile

 

cable (nonmetallic - romex)

cables con manguera

cables revestidos con manguera

 

cloth covered cable

cables con cubierta textile

 

disconnects (main)

dispositivos principales de desconexión

 

electric

eléctrico

 

extension cord

extensión eléctrica

cordón de extension

extensione de energía

prolongadores

 

fault

falla eléctrica 

 

fuse

fusible

 

fuse (cartridge)

fusible de cartucho

 

fuse (plug)

fusible de rosca

 

gfci

los interruptores de circuito para fallas de tierra

los interruptores fusible de seguridad a tierra

fusible de seguridad de tierra (breaker)

interruptor de circuito con pérdida a tierra 

 

ground clamp

abrazadera para conexión de tubos de toma de tierra.

grillete para conexiones de tubos de toma de tierra

picas para conexiones de tubos de toma de tierra

 

ground fault

pérdida de tierra

pérdida a tierra 

 

grounded receptacle

enchufe con conexión a tierra

 

grounding

(service grounding)

conexión a la tierra eléctrica

la puesta a tierra de los equipos de servicio

 

grounding (bare) wire

cable (pelado) a tierra

cable (pelado) de tierra

hilo de tierra

 

grounding rod

conexión a tierra de barra

 

hot wire

(ungrounded cable)

cable de carga

cable de fase

hilo de corriente

 

insulator

aislador

 

junction box

caja de unión eléctrica

caja de conexión

caja de derivación

 

knockout

agujero ciego

 

meter

contador eléctrico

 

nonmetallic cable - romex

cables con manguera

cables revestidos con manguera

 

overcurrent

sobreintensidad de corriente

 

overcurrent protection devices

los equipos de protección contra sobrecargas eléctricas

 

receptacle

enchufe

toma corriente

tomacorriente

receptáculo

 

receptacle — three prong (slot) receptacle

enchufe de triple contactos

 

receptacle — two prong (slot) receptacle.

enchufe de dos contactos

 

service drop

la acometida del servicio

 

service entrance conductors

los conductores de entrada de servicio

los cables de entrada eléctricos

 

service equipment

los equipos de servicio

 

service grounding

conexión a la tierra eléctrica

la puesta a tierra de los equipos de servicio

 

service panel

cuadro de distribución eléctrico

los tableros de distribución eléctrica

 

short circuit

cortocircuito

 

sub panel

cuadro auxiliar de distribución eléctrico

los tableros auxiliares de distribución eléctrica

 

switches

interruptores

 

tape, electrical

esparadrapo 

 

terminal

terminal

 

transformer

transformador

 

voltage

voltaje

tensión

 

white neutral (electric, grounded conductors)

cable (blanco) neutro

hilo neutro

hilo de retorno

 

wire

cables

alambres

hilos

 

wiring

cableado

Reporting Language
Un Estilo de Escribir los Informes

 

 

I tested a representative number of switches and outlets in each room. I did not inspect buried or concealed wires. This is not a code inspection, nor does it include intercoms, remote control devices, alarm systems and low voltage systems.

Yo probé un número representativo de interruptores y enchufes fueron probados en cada cuarto. No inspeccioné los cables enterrados u ocultado. Esto no es una inspección de los código, ni incluye los intercomunicadores, los dispositivos de mando a distancia, los sistemas de alarmar y los sistemas de la baja voltaje.

Cable: I noted brittle/frayed wire insulation. This is a fire hazard.

Observé cubiertos de cables frágil o raído. Esto es un riesgo de incendios

Cables: I noted exposed wire splices. For electrical safety it is important that all wire splices be enclosed in a junction box.

Observé conexiones expuestos de cables eléctricos. Para la seguridad eléctrica es importante que todos las conexiones se adjunten en una caja de unión.

Double tap wiring present. This means that two wires are attached to a breaker/fuse which is designed to accommodate only one wire. This is a potentially dangerous situation which should be corrected for added electrical safety. Refer to a qualified electrician for correction.

[Observé que hay dos cables conectados a un interruptor or fusible diseñado para solamente un cable. Ésta es una situación potencialmente peligrosa que se debe corregir para la seguridad eléctrica agregada. Refiérase a electricista cualificado para la corrección.]

Electricity was not turned on the day of the inspection

No había electricidad en el día de la inspección.

GFCI does not trip when tested. This means that this GFCI receptacle is not providing you with valuable protection. Replacement is necessary.

No salta cuando se prueba. Esto significa que este enchufe no le está proveiendo la protección importante. Su substitución es necesario.

GFCI Note: GFCIs (Ground Fault Circuit Interrupters) are the outlets (or panel box circuit breakers) with the "Test" and "Reset" buttons.  You have seen them in bathrooms and kitchens. They are designed for places where electricity, moisture and people meet. For example, kitchens, bathrooms, basements, crawl spaces, outside outlets, garages, etc. GFCI receptacles are designed to trip (stop supplying electricity) when current strays. They are not expensive (they cost less than many new curtains) and they are an IMPORTANT and HIGHLY RECOMMENDED safety devices.

Nota sobre los GFCI: Los GFCIs (los interruptores de circuito para fallas de tierra) son los enchufes (o los interruptors automático en el cuadro de distribución eléctrico) con los botones de prueba "test" y "reset". Usted lo ha visto en los cuartos de baño y en las cocinas. Se utilizan en los lugares donde la electricidad, la humedad y los humanos se juntan. Por ejemplo, las cocinas, los cuartos de baño, los sótanos, los arrastres, los enchufes de afuera, los garages, etc. Los GFCIs saltan (apagan rápidamente la corriente) cuando hay un disturbio en el flujo eléctrica. No son costosos (ellos cuestan menos que muchas cortinas nuevas) y son aparatos de seguridad IMPORTANTES y ALTAMENTE RECOMENDADOS.

I recommend a GFCI upgrade in this area for added electrical safety.

Recomiendo la instalación de un interruptore de circuito para fallas de tierra (GFCI) en esta área para aumentar la seguridad eléctrica.

Ground connection clamp is corroded, missing or loose. I recommend correction is for added electrical safety.

Observé que la abrazadera para la conexión de tubos de toma de tierra está corroído, flojo o desaparecido. Recomiendo la corrección para la seguridad eléctrica agregada.

Ground: I noted corrosion at the plumbing ground clamp. I recommend correction for added electrical safety.

Observé que la abrazadera para la conexión del tubo de la plomería al toma de tierra está corroída. Recomiendo la corrección para la seguridad eléctrica agregada.

Lighting: I recommend additional lighting near the appliances (heating system, electrical system, plumbing, etc.) for added safety and convenience.

Recomiendo la iluminación adicional cerca de los aparatos (la calefacción, los cuardros eléctrico, la plomería, etc.) para la seguridad y la conveniencia agregada.

Lighting: I suspect a burned out light bulb but this was not verified.

Una bombilla quemada se sospecha pero esto no fue verificado.

Lighting: Cover/dome missing. I suggest replacement.

La tapa está desaparecida. Sugiero el reemplazo.

Lighting: I recommend additional lighting for added safety and aesthetics.

Insuficiente. Recomiendo mas iluminación para aumentar la seguridad y para la estética agregadas.

Panelboard is located in a closet which is not in compliance with generally accepted modern standards. Refer to a qualified electrician for an evaluation.

El cuadro de distribución eléctrico está adentro de un armario. Esto no está en conformidad con estándares modernos. Para la seguridad agregada, permita que un electricista cualificado lo examine.

Panelboard: Cover screws missing: One or more missing cover screws means that the electric panelboard is not closed as tightly as it was designed to be closed. For electrical safety, all manufacturer's instructions must be followed. In addition, a panelboard that is not closed tightly may allow children and small animals (mice) dangerous access. This is a simple but important matter to correct for added safety. Refer to the manufacturer for appropriate (not pointed) cover screws.

Hay uno o más tornillos desaparecidos que son para la tapa del cuadro de distribucion eléctrico. Eso es para decir que el cuadro de distribución eléctrico no está cerrado tan firmemente como fue diseñado por el fabricante. Para la seguridad eléctrica, todas las instrucciones del fabricante se deben prestar la atención. Tambien, un cuadro de distribución eléctrico que no está cerrado firmemente puede permitir los jóvenes y los animales pequeños (ratones) acceso peligroso al cuadro. Esto es algo fácil, pero importante, de corregir para la seguridad agregada. Refiérase al fabricante del cuadro de distribución para los tornillos apropiados (que no sean con puntos).

Panelboard: FPE: There is a Federal Pacific Electric "Stab-Lok" panelboard in the building This panelboard is a latent fire hazard: it's circuit breakers may fail to trip in response to an overcurrent or a short circuit. Failure of a circuit breaker to trip can result in a fire, property damage, or personal injury. A circuit breaker that may not trip does not afford the protection that is intended and required. Simply replacing the circuit breakers is not a reliable repair. The panel should be replaced. Additional information can be read on internet

Este cuadro de distribución eléctrico de este fabricante es un riesgo de incendios latente. Los interruptores puede no poder saltar en respuesta a una sobreintensidad de corriente o a un cortocircuito. La falta de un interruptor de saltar puede causar un incendio, los daños de los materiales, o los daños corporales. Un interruptor que puede no saltar no proporciona la protección intencional y requerida. Simplemente substituir los interruptores no es una reparación confiable. El panel debe ser substituido. La información adicional se puede leer en esta página del internet.

Receptacle: I observed receptacle(s) directly over the electric baseboard heater. This could result in the overheating of electrical wires. For electrical safety I recommend that this (these) receptacle(s) be moved away from the heater(s).

Observé enchufes directamente más arriba que los radiadores eléctricos. Esto puede tener el resultado de la recalentamiento de los cables eléctricos. Para la seguridad eléctrica agregada recomiendo que este (éstos) enchufe(s) estén movido lejos de los radiadores eléctricos.

Receptacle: At least one three prong (slot) receptacle is not properly grounded. Proper grounding is important for electrical safety and this (these) receptacle(s) should be corrected.

Por lo menos un enchufe de triple contactos no tiene conexión eléctrica a la tierra. La conexión a la tierra eléctrica apropiado es importante para la seguridad y este (éstos) enchufe(s) deben ser corregido.

Receptacle: Cracked or chipped outlet should be replaced for added electrical safety.

El enchufe agrietado o fragmentado se debe substituir para la seguridad eléctrica agregada.

Receptacle: Insufficient number of receptacles lead to the dangerous substitution of extension-cord wiring for permanent wiring. I recommend the installation of additional receptacles for added safety.

Escaso de los enchufes conduce la substitución peligrosa de los extensiones de energía para los cables permanente. Recomiendo que usted instale enchufes adicionales para la seguridad agregada.

Receptacle: I noted a loose or improper attachment of at least 1 receptacle in this (these) rooms. I recommend correction for added electrical safety.

Enchufe flojo: Conexión flojo o incorrecto (en por lo menos de un enchufe o receptáculo en este (éstos) cuartos). La corrección es necesaria para la seguridad eléctrica agregada.

Receptacle: Missing receptacle covers should be replaced for added electrical safety.

Las tapas que faltan de los enchufes se deben reemplazar para la seguridad eléctrica agregada.

Receptacle: No receptacle. Insufficient number of receptacles lead to the dangerous substitution of extension-cord wiring for permanent wiring.  I recommend the installation of receptacles for added safety.

Ningúno. Insuficient enchufes conduce la substitución peligrosa del cableado de extensiones en vez de los enchufes. Para mas seguridad, recomiendo la instalación de mas enchufes.

Receptacle: Painted receptacles restrict proper operation, I recommend that the painted receptacles be replaced.

Los enchufes pintados restringen el funcionamiento apropiado. Recomiendo la substitución.

Receptacle: Reverse polarity observed. Receptacle slots are of unequal widths. The long one should be neutral, the short one should be hot. This is not the case with at least one receptacle. This situation is potentially dangerous and correction is necessary for electrical safety.

Observé la polaridad reversa. Las ranuras de los enchufes tienen anchuras desiguales. El largo debe ser neutral, el corto debe tener carga. Ésto no es el caso (en por lo menos un enchufe en este (estos) cuarto(s)). Esta situación es potencialmente peligrosa y la corrección es necesaria para la seguridad eléctrica.

Refer to a qualified electrician for repairs

Refiérase a electricista cualificado para las reparaciones

Refer to a qualified electrician.

Refiérase a un electricista cualificado.

Refer to a qualified electrician. (Allow a qualified electrician to examine it.)

Permita que un electricista cualificado lo examine.

Service entrance conductors: Please note that the evaluation of the electric entrance wires (the outside wires which provides electricity from the electric company) is in the Exterior portion of this inspection report.

Los cables de la entrada eléctricos son los cables exteriores que traen la electricidad de la compañía eléctrica. Observe, por favor, que la evaluación de estos cables está en la sección de "Exterior" en este informe.

Service entrance conductors: Trees are touching or too close to power lines. The tree limbs must be cut back. This is an electrical safety issue. Refer to a qualified tree service contractor.

Los árboles tocan o están demasiado cerca de los cables eléctrica. Las ramas del árbol se deben cortar. Esto es una necesidad de seguridad eléctrica. Permita que un contratista cualificado lo examine.

Subpanel neutral-grounding wires bonded. This panel is a subpanel of the a main panel. In a subpanelboard, the white neutral and the grounding wire must not be bonded together as it is in this case. Correction is necessary for added safety. Refer to a qualified electrician.

Este cuadro de distribución eléctrico es un cuadro auxiliar del cuadro de distribución eléctrico principal. En un cuadro auxiliar, los cables (blanco) neutro y los cables (pelado) a tierra no deben ser jamás enlazados como están en este caso. La corrección es necesaria para la seguridad agregada. Permita que un electricista cualificado lo examine.

Home Inspection Reporting Language

Translated from English to Spanish

Un Estilo de Escribir los Informes de las Inspecciones de Viviendas

Traducido de Inglés al Español

Expert home and building inspections in NY's Hudson Valley, NYC's five boroughs and NY's Nassau County

October Home Inspections

call (866) 628-1084

Las inspecciones de vivienda experta con los informes ambos en español y en inglés en el Valle del Río Hudson en NY, en NYC, y en el condado de Nassau en Long Island.

October Home Inspections

llame (866) 628-1084

  

Corrections and comments are encouraged.